Know what's inside:

Analyses made in Germany

GBA Group - Neuried

More than 45 years of experience in GMP analyses made in Germany.

Over time, regulatory requirements have evolved. We have kept up and evolved with them. As a result, we are proud of the quality system as it is today. We look forward to the challenges of the future and will continue to develop the system in the spirit of continuous improvement.

The two laboratory sites have grown and improved over more than 45 years. One of the major milestones in recent years has been the relocation and simultaneous merger of the two laboratory sites near Munich. We are delighted to have been operating at the new site in Neuried for more than two years and to continue our story at this site.

Laboratory Information & Management System (LIMS)

A LIMS database is used to register and manage samples, references, instruments, sample results and processes such as OOS or deviation procedures. The latest innovation in this area is the use of smart labels, which can indicate in real time whether an instrument has been approved for analyses. These smart labels are controlled via the LIMS. In addition, automated results reports (CoA, RoA) can be generated using the system. This ensures consistent reporting of your results.

Chromatography

Centralized software capable of running all chromatography instruments. It is used to control the chromatography systems and evaluate the data collected. The software is validated and Part 11 compliant. The software always uses the same algorithms to determine a peak, regardless of the instrument used.

Laboratory documentation

Laboratory reports are automatically issued and tracked by the LIMS. Weighing documentation is digital and includes an audit trail entry. The software for weighing is Part 11 compliant. Thankfully, the days of weighing print outs are over.

Harmonized processes at both laboratory sites - the same SOPs in the main processes apply

The two GMP laboratory sites in Ulm and Neuried have a harmonized Quality Assurance system. The main processes are harmonized and the same documents apply at both sites. The training courses are centrally controlled and monitored by a Quality Management team. This ensures that you receive the same quality at both locations. If the measurement technology is available at both sites, then the two laboratories are interchangeable or, in other words, redundant.

Harmonized core processes:
• OOS / OOE
• Deviation
• Corrective and Prevantive Action (CAPA)
• Change Control
• Risk assessment
• Data Integrity
• LIMS
• Chromatography software
• Software for titrators and balances
• Cutting and rounding of values
• Audits
• Qualification of Instruments
• Validation of analytical methods
• Analytical method transfer
• Verification
• Supplier qualification and subcontraction
• Document management system
• Complaint
• and a whole lot more

About GBA Group - GMP Labs

We are continuously working on the automated evaluation and reporting of results. Our goal is to become a ‘paperless’ laboratory.

We look forward to welcoming you as our client.

Quality Standard
• GMP AMWHV §14 (EU GMP Guideline and respective German implementation)
• cGMP (21CFR 210 and 211)
• GMP AMWHV §13 (EU GMP Guideline and respective German implementation)
• non-GMP

For a more detailed information about the GBA Group GMP testing sites please click here.

What types of materials are most commonly analyzed under GMP by GBA Group?

• API
• FDF (e. g. tablet, creme, syrup, suppository, pellets…)
• Excipients
• Packing material
• Ingredients
• Additives
• others

European Pharmacopoeia and United States Pharmacopeia

We have a high level of expertise in the testing of parameters such as:

Dissolution and Disintegration

Ph. Eur. chapter

2.9.3. Dissolution test for solid dosage forms
2.9.42. Dissolution test for lipophilic solid dosage forms
2.9.43. Apparent dissolution
ICH Q4B Annex 7R2
2.9.1. Disintegration of tablets and capsules
2.9.2. Disintegration test for solid rectal and vaginal dosage forms

USP / NF chapter

〈711〉 Dissolution
ICH Q4B Annex 7R2
〈701〉 Disintegration

Particulate Contamination and Particle Size Distribution

Ph. Eur. chapter

2.9.20. Particulate contamination: visible particles
2.9.19. Particulate contamination: sub-visible particles
2.9.31. Particle size analysis by laser light diffraction

USP / NF chapter

〈790〉 Visible Particulates in Injections
〈788〉 Particulate Matter in Injections
〈429〉 Light Diffraction Measurement of Particle Size

Identification

Ph. Eur. chapter

2.2.24. Absorption Spectrophotometry, Infrared
2.3.1. Identification reactions of ions and functional groups

USP / NF chapter

〈197〉 Spectroscopic Identification Tests
〈191〉 Identification Tests—General

Appearance of solution

Ph. Eur. chapter

2.2.1. Clarity and degree of opalescence of liquids
2.2.2. Degree of coloration of liquids

USP / NF chapter

〈630〉 Visual Comparison
〈855〉 Nephelometry and Turbidimetry

Assay Tests

Ph. Eur. chapter

e. g.
2.5.1. Acid value
2.5.3. Hydroxyl value
2.5.6. Saponification value
2.5.11. Complexometric titrations
2.5.12. Water: semi-micro determination
2.5.32. Water: micro determination
2.5.29. Sulfur dioxide
2.5.30. Oxidising substances
2.5.33. Total Protein e. g. Bradford, Lowry

USP / NF chapter

e. g.
〈921〉 Water Determination
〈401〉 Fats and Fixed Oils
〈525〉 Sulfur Dioxide
〈507〉 Protein Determination Procedures e. g. Bradford, Lowry

Gravimetric Test

Ph. Eur. chapter

2.2.32. Loss on drying

USP / NF chapter

〈731〉 Loss on Drying

Limit Tests

Ph. Eur. chapter

e. g.
2.4.3. Calcium
2.4.4. Chlorides
2.4.6. Magnesium
2.4.8. Heavy metals
2.4.9. Iron
2.4.13. Sulfates
2.4.14. Sulfated ash
2.4.16. Total ash
Acidity or alkalinity reducing substances

USP / NF chapter

e. g.
〈281〉 Residue on Ignition
〈221〉 Chloride and Sulfate
〈231〉 Heavy Metals

Other Tests

Ph. Eur. chapter

e. g.
2.9.5. Uniformity of mass of single-dose preparations
2.9.40. Uniformity of dosage units
2.2.9. Capillary viscometer method
2.2.10. Viscosity -Rotating viscometer method
2.2.5. Relative density
2.2.6. Refractive index
2.2.20. Potentiometric titration
2.9.8. Resistance to crushing of tablets
2.2.7. Optical rotation (specific optical rotation)
2.8.4. Swelling index
2.2.35. Osmolality
2.9.39. Water-solid Interactions: determination of sorption-desorption isotherms and of water activity

USP / NF chapter

e. g.
〈905〉 Uniformity of Dosage Units
〈1911〉 Rheometry
〈841〉 Specific Gravity
〈831〉 Refractive Index
〈541〉 Titrimetry
〈1217〉 Tablet Breaking Force
〈781〉 Optical Rotation
Swell Volume
〈785〉 Osmolality and Osmolarity
〈922〉 Water Activity

Packaging Material Testing

  • Glass Containers (Ph.Eur. 3.2.1 / USP <660>)
  • Plastic Materials and Containers (Ph.Eur. 3.2.3 to 3.2.6 / USP <661>, <671>)
  • Rubber Seals (3.2.9 / <381>)
  • Silicon Elastomers (3.1.9)
  • Container Closure Integrity Tests (CCIT)
  • Extractables & Leachables Studies

Instrumentation Analyses

Instruments for qualitative and quantitative approaches:
• Assay
• Limit Tests
• Related substances
• Residual solvents

Instrumentation Details

HPLC:

  • VWD / DAD
  • Refraction index
  • ECD (electrochemical)
  • CDD (conductivity)
  • CAD (charged aerosol)
  • FLD (fluorescence)

UHPLC:

  • MS
  • VWD / DAD
  • CAD (charged aerosol)
  • FLD (fluorescence)

GC:

  • Head-space
  • direct
  • FID
  • MS

Spectroscopy:

  • ICP-MS
  • ICP-OES
  • AAS / AES (hybrid system)
  • Microwave digestion available

Potentiometric Titration:

  • several electrodes available

Limit Tests and Assays

Elemental impurities / Screening

  • 2.4.20. Determination of elemental impurities
  • 〈232〉 Elemental Impurities—Limits
  • ICH Q3D

Composition of fatty acids

  • 2.4.22. Composition of fatty acids by gas chromatography
  • 〈401〉 Fats and Fixed Oils

Residual solvents

  • 2.4.24. Identification and control of residual solvents
  • 〈467〉 Residual Solvents
  • 〈1467〉 Residual Solvents—Verification Of Compendial Procedures And Validation Of Alternative Procedures

Ethylene oxide and dioxan

  • 2.4.25. Ethylene oxide and dioxan
  • 〈228〉 Ethylene Oxide and Dioxane
  • 〈469〉 Ethylene Glycol, Diethylene Glycol, and Triethylene Glycol in Ethoxylated Substances

N-Nitrosamine

  • untargeted screening

Uniformity of dosage units

  • 2.9.6. Uniformity of content of single-dose preparations
  • 2.9.40. Uniformity of dosage units
  • 〈905〉 Uniformity of Dosage Units

Microbial contamination

Our GBA Group site located in Ulm (Germany) offer microbiological tests.

Learn more about our microbiological tests here.

Stability Testing - Comprehensive Service

In the field of stability testing, we offer a comprehensive service for human and veterinary medicinal products as well as for medical devices.

Our service includes consulting and planning of your stability studies as well as all necessary testing and quality assessments.

• Storage of your samples under the required conditions (e.g. ICH conditions and special conditions)
• Stability study sample management
• Perform the pre-planned analyses on stability samples as scheduled

Learn more about our Stability Testing Services here.

GMP Prüfungen

Kontaktieren Sie uns!

Für mehr Informationen über uns oder unsere Dienstleistungen schreiben Sie uns gerne!

Kontakt
Kontaktformular

Kontakt

Sie haben Fragen zu unseren Services?

Kontaktformular

Das erfahrene und sehr engagierte Team der GBA Group bietet Ihnen eine Vielfalt an verschiedenen Dienstleistungen in den folgenden Gebieten an.

GBA Pharma Labs - GMP Prüfung

GMP Prüfung

Mehr
GBA Pharma Labs - GMP-Qualitätskontrolle

GMP-Qualitätskontrolle

GBA Pharma Labs - Methodenentwicklung & Validierung

Methodenentwicklung & Validierung

GBA Pharma Labs - Stabilitätsstudien

Stabilitätsstudien

GBA Group - Dissolution

Dissolution

GBA Pharma Labs - Extractables & Leachables Studien

Extractables & Leachables Studien

GBA Pharma Labs - Prüfung von Verpackungsmaterial

Prüfung von Verpackungsmaterial

GBA Pharma Labs - Partikel-Bestimmung

Partikel-Bestimmung

GBA Pharma Labs - Prüfung auf Elementverunreinigungen (Elemental Impurities)

Prüfung auf Elementverunreinigungen (Elemental Impurities)

GBA Pharma Labs - Mikrobiologie

Mikrobiologie

GBA Pharma Labs - Regulatorische Dienstleistungen

Regulatorische Dienstleistungen

GBA Pharma Labs - Aminosäure Analytik

Aminosäure Analytik

GBA Pharma Labs - Geräteausstattung

Geräteausstattung

GBA Pharma Labs - N-Nitrosamine

N-Nitrosamine

GBA Pharma Labs - qPCR

qPCR

GBA Pharma Labs - iCEF

cIEF

GBA Pharma Labs - Proteincharakterisierung

Proteincharakterisierung

GBA Pharma Labs - Diethylenglykol (DEG) und Ethylenglykol (EG) mittels GC

Diethylenglykol (DEG) und Ethylenglykol (EG) mittels GC

Bioassay

Bioassay

© 2025 GBA Group

Folgen Sie uns

  • linkedIn GBA Pharma
  • xing
  • GBA youtube
  • gba Instagram
KontaktDatenschutzRechtliche HinweiseAGBImpressum